Table 39: The recommended brake resistor types, mains voltage 525-690 V
Frame Drive type Duty cycle Type of brake resistor Resistance [Ω]
MR5 0004-0011 Light duty BRR 0013 LD 6 100
Heavy duty BRR 0013 HD 6 100
MR6 0007-0013 Light duty BRR 0013 LD 6 100
Heavy duty BRR 0013 HD 6 100
0018-0034 Light duty BRR 0034 LD 6 30
Heavy duty BRR 0034 HD 6 30
MR7 0041 Light duty BRR 0034 LD 6 30
Heavy duty BRR 0034 HD 6 30
0052-0062 Light duty BRR 0052 LD 6 18
Heavy duty BRR 0052 HD 6 18
MR8 0080 Light duty BRR 0052 LD 6 18
Heavy duty BRR 0052 HD 6 18
0100-0125 Light duty BRR 0100 LD 6 9
Heavy duty BRR 0100 HD 6 9
MR9 0144 Light duty BRR 0100 LD 6 9
Heavy duty BRR 0100 HD 6 9
0170-0208 Light duty BRR 0208 LD 6 7
Heavy duty BRR 0208 HD 6 7
The light duty cycle is for brake resistor cyclic use (1 LD pulse in a 120-second period).
The light duty resistor is rated for a 5-second ramp from full power to 0.
The heavy duty cycle is for brake resistor cyclic use (1 HD pulse in a 120-second period).
The heavy duty resistor is rated for a 3-second full power braking with a 7-second ramp
to 0.