9.2 VACON
®
100 FLOW - TECHNICAL DATA
Table 49: The technical data of the Vacon
®
100 FLOW AC drive
Technical item or function Technical data
Mains connection
Input voltage U
in
208-240 V, 380-500 V, 525-600 V, 525-690 V, -10%…
+10%
Input frequency 50-60 Hz, -5...+10%
Connection to mains Once per minute or less
Starting delay 6 s (MR4 to MR6); 8 s (MR7 to MR9)
Mains
Mains types: TN, TT, and IT
Short circuit current: the maximum short circuit
current must be < 100 kA.
Motor connection
Output voltage 0-U
in
Continuous output current
I
L
: Ambient temperature max. +40 °C overload 1.1 x I
L
(1 min/10 min)
Output frequency 0-320 Hz (standard)
Frequency resolution 0.01 Hz
TECHNICAL DATA, VACON® 100 FLOW VACON · 139