Syntax Description
Example:
...
RH= 25.10% T= 24.77'C
RH= 25.12% T= 24.96'C
s
Table 16 Intv Command
Syntax Description
intv<cr>
Use the intv command to show or set the output
interval of the serial line measurement messages
(applies when r command or RUN mode is
used). The shortest output interval is one
second. This command has no eect on the
operation of the analog outputs.
intv [iii uuu]<cr>
Set the output interval.
iii = interval, range 0 ... 255.
u = unit for interval setting:
• s = seconds
• min = minutes
• h = hours
If you set the interval to 0, the output messages
are output as quickly as they are generated,
without additional delay.
Example:
intv 5 s
Output interval: 5 S
>
Table 17 Send Command
Syntax Description
send [x] <cr>
Use the send command to output a single
measurement reading from the transmitter.
When you enter the x parameter, the transmitter
will output RH + T value in predefined format
regardless of what quantities are selected.
Chapter 4 – Serial Line Operation
33