76
Model Code Page
21. Engine
1. 9. 1992
6000--8750
216 2
4. Check the shaft end float . Place the stylus of the dial gauge
against the end of the shaft and move the shaft axially. Refer
to the clearance given in the specifications on page 210/9.
If any defects or wear are confirmed, the turbocharger should
be reconditioned.
If the engine does not work correctly and the turbocharger is
not defective or too worn, the fault coul d be traced to one of
the following items:
--- Blocked air filter
--- Leakage in the inlet or exhaust systems. Leaking flange
seal
--- Defective or wrongly adjusted injection pump.
--- Wrongly adjusted throttle linkage
--- Defective or wrongly adjusted injectors
--- Low fuel pressure (e.g. blocked fuel filter)
--- Low compression, wrong valve clearance