2920 Float & Tape Transmitter MODBUSAppendix A — MODBUS Implementation
160 Installation and Operations Manual
20 Coded Level Units (Setup > Lev Disp Units)
45 - METERS
44 - FEET
47 - INCHES
241 - FT-IN-16THS
240 - 16th of an INCH
49 - MILLIMETERS
243 - FT - IN - 8THS
21 Coded Temp Units (Setup > Temp Disp Units)
32 - C
33 - F
22 Coded Level Type (Setup > Enc Direction)
0 - FORWARD
1 - REVERSE
23 Coded Temp Type (Setup > RTD Type)
0 - Pt100
1 - Cu100
2 - Cu90
3 - None
24 Scaled Manual Temperature (Tank > Manual Temp)
25 Integer Max Integer Value
26 Coded Gauge Type (Setup > Gauge Type)
0 - Metric
1 - English
27 Scaled Calibration Level (Setup > CalLevel)
28 Integer Enc Command
0 - No Action
1 - Align Sensors
29 Reserved Reserved
30 Tag Firmware Version (characters 1 & 2)
31 Tag Firmware Version (characters 3 & 4)
32 Tag Firmware Version (characters 5 & 6)
33 Tag Firmware Version (characters 7 & 8)
34 Tag Firmware Version (characters 9 & 10)
35 Scaled Value
36 Scaled Value
37 Scaled Value
38 Integer AI Status (Analog Input > Analog Status)
39 Integer AI Filter (Analog Input > Avg Filter)
Register Number Type Description