VTK‐VS‐BA‐004e‐B|UserManualMDS3200A | Communication Interfaces
48
27. WRITE:LCD:<text>
Description: Withthiscommand,anASCIItextincludingupto32characterscanbe
writtenonthescreen.Allofthelettersappearinformofcapitalletters.
Example:
Input: WRITE:LCD:HelloWorldorWRITE:LCD:HELLOWORLD
Result: TheLC‐Displayshows:
HELLOWORLD
Return: OK
28. SYSTEM:SHOW:CYCLES
Description: Thecurrentvalueofthecyclecounterisindicated.
Example:
Input:SYSTEM:SHOW:CYCLES
Result: Thevalueappearsintheformofastring.
Return:1235000
29. SYSTEM:SHOW:VALVEID
Description: ThevalveIDappears(e.g.whenconsultingourTechnicalSupport).
Example:
Input: SYSTEM:SHOW:VALVEID
Result: IDoftheconnectedvalve.
Return: 11CW36
30. SYSTEM:SHOW:CONTROLLERID
Description: TheIDofthecontrolunitisdisplayed.
Example:
Input: SYSTEM:SHOW:CONTROLLERID
Result: IDofthecontrolunit.
Return: 3050
31. *OPC?
Description: Monitoringthelasttriggerimpulses.
Afterthis,thecounterisclearedtozero.
Example:
Input: *OPC?
Result: Numberofthelastpulses.Clearthecountertozero.
Return: 669
32. TAPPET:CLEAR
Description: Thecounterfortappetmaintenanceiscleared.Thisinstructionisusually
enteredattheendofthemaintenanceprocedure.
Example:
Input: TAPPET:CLEAR
Result: Counterresetto“0“.
Return: OK