11
Examples
OUTPut1:STATe ON
sets the instrument CH1 output to ON.
*RST (No Query Form)
This command resets the instrument to the factory default settings.
Syntax
*RST
Arguments
None
Examples
*RST
resets the instrument settings to the factory defaults.
[SOURce[1|2]]:AM[:DEPTh]
This command sets or queries the modulation depth of AM modulation for the specified
channel. Set the modulation depth from 0% to 100% with resolution of 1%.
Syntax
[SOURce[1|2]]:AM[:DEPTh] {<depth>|MINimum|MAXimum}
[SOURce[1|2]]:AM[:DEPTh]? [MINimum|MAXimum]
Arguments
<depth>::=<NR2>[<units>]
where:
<NR2> is the depth of modulating frequency.
<units>::=PCT
MINimum sets the modulation depth to minimum value. MAXimum sets the modulation
depth to maximum value.
Returns
<depth>