EasyManua.ls Logo

VOLTCRAFT FG-1602 - [Source[1|2]]:Sweep:source; [Source[1|2]]:Sweep:spacing

VOLTCRAFT FG-1602
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
Returns
<percent>
Examples
SOURce1:PWM:DEViation:DCYCle 5.0
sets the CH1 PWM deviation to 5.0%.
[SOURce[1|2]]:SWEep:SOURce
This command sets or queries the trigger source in the sweep mode for the specified
channel.
Syntax
[SOURce[1|2]]:SWEep:SOURce [TIMer|MANual|EXTernal]
[SOURce[1|2]]:SWEep:SOURce?
Arguments
TIMer specifies an internal clock as the trigger source.
MANual specifies a manual trigger input as the trigger source.
EXTernal specifies an external trigger input as the trigger source.
Returns
TIM|MAN|EXT
Examples
SOURce1:SWEep:SOURce EXTernal
sets an external trigger input as the trigger source in the sweep mode.
[SOURce[1|2]]:SWEep:SPACing
This command selects linear or logarithmic spacing for the sweep for the specified
channel.
The query returns the type for the sweep spacing for the specified channel.
Syntax
[SOURce[1|2]]:SWEep:SPACing {LINear|LOGarithmic}
[SOURce[1|2]]:SWEep:SPACing?
Arguments
LINear sets the sweep spacing to linear.

Table of Contents