35
<units>::=[RAD|DEG]
If <units> are omitted, RAD is specified automatically. The setting ranges are:
RAD: 0 to +2 PI, relative to phase value
DEG: 0 to +360, relative to phase value
Returns
<phase>
Examples
SOURce1:PHASe:ADJust MAXimum
sets the maximum value for the phase of CH1 output waveform.
[SOURce[1|2]]:PM[:DEViation]
This command sets or queries the phase deviation of PM modulation for the specified
channel.
Syntax
[SOURce[1|2]]:PM[:DEViation] {<deviation>|MINimum|MAXimum}
[SOURce[1|2]]:PM[:DEViation]? [MINimum|MAXimum]
Arguments
<deviation>::=<NR3>[<units>]
where:
<NR3> is the phase deviation.
<units>::=[RAD|DEG]
If <units> are omitted, RAD is specified automatically. The setting ranges are:
RAD: 0 PI to +1 PI, relative to phase value
DEG: 0 to +180, in 1 degree steps, relative to phase value
Returns
<deviation>
Examples
SOURce1:PM:DEViation MAXimum
sets the maximum value for the CH1 phase deviation of PM modulation.