18
Examples
SOURce1:BPSKey:STATe ON
enables the CH1 BPSK modulation.
[SOURce[1|2]]:BURSt:GATE:POLarity
This command sets the generator to output a burst when the gated signal at the
[Ext Trig/Burst/Fsk In] connector at the rear panel is high level or low level.
This command is only available in gated Burst mode.
Syntax
[SOURce[1|2]]:BURSt:GATE:POLarity{NORMal|INVerted}
[SOURce[1|2]]:BURSt:GATE:POLarity?
Arguments
NORMal sets the polarity to Normal.
INVerted sets the polarity to Inverted.
Returns
NORM|INV
Examples
SOURce1:BURSt:GATE:POLarity INVerted
sets the polarity to INVerted, means the instrument outputs a burst when the gated signal
at the [Ext Trig/Burst/Fsk In] connector at the rear panel is low level.
[SOURce[1|2]]:BURSt:INTernal:PERiod
This command sets or queries the Burst period for the specified channel.
Syntax
[SOURce[1|2]]:BURSt:INTernal:PERiod {<period>|MINimum|MAXimum}
[SOURce[1|2]]:BURSt:INTernal:PERiod?[MINimum|MAXimum]
Arguments
<period>::=<NRf>[<units>]
where
<NRf> is the Burst period.
<units>::=[ns|us|ms|s]