EasyManua.ls Logo

Wacker Neuson ET18 - Coolant; Noise Emissions

Wacker Neuson ET18
298 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-8 OM ET18/20/24 us 1.3 * et18_20_24t900.fm
9
9.10 Coolant
Compound table
9.11 Noise emissions
Information
Measurements performed on asphalted surface.
Outside temperature
1
1. Use the 1:1 concentration for warm outside temperatures, too, to ensure protection against corrosion,
cavitation and deposits.
Water Coolant
2
2. Do not mix the coolant with other coolants.
Up to °C (°F)
% by vol-
ume
% by volume
37 (34.6) 50 50
ET 18 ET 20 ET 24
(Yanmar 3TNV76-SNSE12)
Measured sound power level
LwA
1
1. According to ISO 6395 (EC Directives 2000/14/EC and 2005/88/EC)
92.8 dB (A) 92.8 dB (A) 92.8 dB (A)
Guaranteed sound power level
LwA
1
93 dB (A) 93 dB (A) 93 dB (A)
Uncertainty factor KpA
2
2. According to EN ISO 4871 (EC Directives 2000/14/EC and 2005/88/EC)
0.8 0.8 0.8
Operator-perceived sound pres-
sure level LpA
3
3. According to ISO 6394 (EC Directives 84/532/EEC, 89/514/EEC, 95/27/EEC)
75.8 dB (A) 75.8 dB (A) 75.8 dB (A)

Table of Contents