BA 357-00 * 3.0 * 35700_07_Wartung.fm 7-83
Maintenance 7
Cleaning the heat exchanger (condenser)
CAUTION
Risk of injury due to hot parts!
Touching hot components can result in injury.
Allow the machine to cool down.
Wear protective equipment.
1. Apply the parking brake.
2. Turn the machine off and remove the ignition key.
3. Remove cover A from the protective screen.
4. Clean heat exchanger C with a water jet
(do not use a high-pressure cleaner or compressed air).
5. Clean the air-intake area at the protective screen.
6. Install the cover A.
Information
Dehumidifier B has to be replaced
every 2 years by an authorized service center.
Fig. 257
A
B
C