7-70 BA 357-00 * 3.0 * 35700_07_Wartung.fm
7 Maintenance
7.11 Heating and ventilation
Important information on cabin ventilation
The cabin is equipped with a fine-dust filter.
CAUTION
Risk to health if fine-dust filter is not correctly mounted or damaged!
An incorrectly mounted or damaged fine-dust filter can cause health
damage to respiratory tracts.
Replace damaged or dirty fine-dust filter with a new one!
Clean the fine-dust filter every 20 operating hours, however replace it
every 500 operating hours at the latest.
The machine may not be used in an environment requiring protection
against aerosols and vapors!
The fine-dust filter does not protect against substances that could
damage health and is therefore not approved for spray work.