BA 357-00 * 3.0 * 35700_09_Technische_Daten.fm 9-9
Technical data 9
9.8 Electrical system
Battery
Light bulbs
Designation
Type
AGM
Manufacturer Hoppecke
Designation trak \ systemize
Rated voltage 80 V
Nominal capacity
416 Ah /
40 cell blocks
Weight 1240 kg (2734 lb)
Operating temperature -15 to +45° (5 to 113 °F)
Storage temperature
1
1. With fully charged battery
-15 to +45 °C
2,
3
(5 to 113 °F)
2. Storage at -15 °C to 0 °C when the battery is connected for trickle charging is permissible.
3. When storing at above 0° C without trickle charging, then perform an open-load voltage measurement
every 3 months.
Service life earthworks
4
4. During continuous operation without pause and the environmental temperature is above 20 °C.
min. 3 h
Service life light work
4
min. 5 h
Charge temperature
-5 to +45 °C
(23 to 113 °F)
Charge duration 5 to 8.5 hours
5
5. Depending on the discharge state of the battery
Angle of inclination
6
6. Not critical in operation. Only park on level ground.
45°
7
7. Observe the tilting limit of the machine: 20° lateral inclination
Battery charger Integrated
Designation Power
Light bulb – high beam (left/right) 24 V, 55 W/H3
Light bulb – low beam (left/right) 24 V, 55 W / H7
Light bulb – parking light (left/right) 24 V 4 W
Light bulb – front and rear turn indicators
(left/right)
24 V 21 W
Light bulb – brake/rear lights
(left/right)
24 V, 21/5 W
Light bulb – working light 24 V, 55 W/H3
Light bulb – rotating beacon 24 V, 55 W / H1
Light bulb – interior light 24 V 10 W