9-10 BA 357-00 * 3.0 * 35700_09_Technische_Daten.fm
9 Technical data
HV components
Power electronics
Designation
Housing protection IP 64
Fan protection IP 55
Operating temperature
-10 to +45 °C
1
(14 to 113 °F)
1. When temperature on heats sink rise above 70 °C, drive control output is reduced
in three stages, depending on the temperature.
Storage temperature
-40 to +85 °C
(-40 to 185 °F)
Weight 12 kg (26.45 lb)
Input voltage 80 V DC
Max. input current on +UB(B) 100 A
Max. input current on +UB 450 A
Standby current 40 mA
Output voltages 80 V DC and 24 V DC
Output power
500 W continuous
700 W p
Output power hydraulic motor control 32 kVA
Output power operating motor control 20 kVA
StVZO module
Designation
Housing protection IP 64
Operating temperature
-10 to +45 °C
(14 to 113 °F)
Storage temperature
-40 to +85 °C
(-40 to 185 °F)
Weight 2 kg (4,4 lb)
Input voltage 80 V DC
Max. input current 15 A1
Standby current 50 mA
Output voltage 24 V DC
Output power 400 W

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson KRAMER 5055e and is the answer not in the manual?

Wacker Neuson KRAMER 5055e Specifications

General IconGeneral
BrandWacker Neuson
ModelKRAMER 5055e
CategoryFront End Loaders
LanguageEnglish

Related product manuals