8-40 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
8.4 Malfunctions in the air conditioning system (opt)
Only authorized service centers and trained personnel may perform
repairs, and fill up and empty the air conditioning system!
Malfunctions in
the air conditioning system
Possible causes Remedy
See
page
Fan does not run
Malfunctioning or loose fuse Replace fuses 7-64
Interrupted line
Contact an authorized service
center
Malfunctioning fan motor
Malfunctioning fan switch
Fan cannot be switched off
Short circuit in cable or fan
switch
Reduced fan output
Dirty contacts
Undersized electric lines
Condenser very dirty Cleaning the condenser 7-81
Insufficient heating output or
none at all
Condenser fins dirty Cleaning the condenser 7-81
Dirty filter Clean the filter 7-71
Loss of refrigerant on equipment
Loose hose connection
Contact an authorized service
center
Damaged hose
Condenser damaged
Compressor does not run
Malfunctioning controls
Loose connection on compressor
Condenser overflow
Expansion valve is stuck in open
position
Contact an authorized service
center
Clogged condenser Dirty radiator fins Clean the condenser 7-81

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson KRAMER 5055e and is the answer not in the manual?

Wacker Neuson KRAMER 5055e Specifications

General IconGeneral
BrandWacker Neuson
ModelKRAMER 5055e
CategoryFront End Loaders
LanguageEnglish

Related product manuals