9-8 BA 357-00 * 3.0 * 35700_09_Technische_Daten.fm
9 Technical data
Hydraulic protection on control valve
Lift and tilt cylinder speed
Usable consumer pressure at 3rd control circuit
Designation
Hydraulic pump
19 cm³/U 54 l/min
(1.16 in
3
/U 14.26 gpm) 3000 min
-1
Max. operating pressure
1
1. Measured at control valve test connection
235 bar (3408 psi)
Tilt cylinder
Secondary protection:
Rod side 260 bar (3715 psi)
Base side 120 bar (1715 psi)
Lifting cylinder
Secondary protection:
None on rod side
Base side 260 bar (3715 psi)
Quickhitch cylinder
Secondary protection:
260 bar (3715 psi)
Designation
Hydraulic pump
19 cm
3
/U 54 l/min
(1.16 in³/U 14.26 gpm) 3000 min
-1
Lifting cylinder
Raise 5.2 s
Lower 3.3 s
Tilt cylinder
Tilt in 2.8 s
Tilt out 3.2 s
Designation
Hydraulic pump Function
Rpm / l/min / bar
(rpm
-1
/gal/min/psi)
Quick couplers
Front 3rd control
circuit
1
(without pressureless
return)
1. In case of higher motor temperatures, the oil flow is automatically reduced.
3rd control circuit
control valve
3000 / 37 / 170
(3000 / 9.78 / 2175)
At coupling block
3rd control circuit quick
couplers
(without
pressureless return)
3rd control circuit
control valve
3000 / 44 /170
(3000 / 11.62 / 2175)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson KRAMER 5055e and is the answer not in the manual?

Wacker Neuson KRAMER 5055e Specifications

General IconGeneral
BrandWacker Neuson
ModelKRAMER 5055e
CategoryFront End Loaders
LanguageEnglish

Related product manuals