7-86 BA 357-00 * 3.0 * 35700_07_Wartung.fm
7 Maintenance
Measures for maintaining anticorrosive protection
WARNING
Special hazards during anti-corrosion protection!
Handling chemical substances can cause serious injury or death.
When handling chemical substances of any kind, such as solvents,
wax, etc., observe the specific product-related safety regulations
(safety data sheet).
Ensure sufficient room ventilation.
Do not use unprotected lights or open flames.
Do not smoke.
Only work on the electrical system if the battery connector has been
disconnected!
Information
Maintenance intervals see "Maintenance plan" on page 7-6.
Cleaning
NOTICE
Contrary to the instructions in section„Cleaning and maintenance on
page 7-19, do not clean machines with anticorrosion protection with a
bristle brush nor with a steam jet or a high-pressure cleaner!
If cleaning the machine with these means cannot be avoided, check
the wax coating very carefully and have it renewed or reapplied as
required.
If the machine is used in corrosive environment over a longer period of
time, remove the floor mat in the cabin. This will avoid a collection of
corrosive moisture.
Thoroughly clean machines that are put out of operation over a longer
period of time.
Clean the machine at least once a week. In particular, remove
corrosive deposits (such as salt crusts) as fast as possible.
Clean the machine with cold running water preferably.