Loading...
8-14 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Main contactor
Error code FMI
Warning
light
Error description Remedy
519866
2
Red
K117 – Contact battery voltage
Signal is faulty or irregular
– Machine goes into emergency shutdown
Critical error
1. Unlock motor isolating
switch
2. Turn off the machine and
then turn it on again.
3. If the error occurs again:
have the error corrected by
an authorized service
center.
7
Red
K117 – Contact battery voltage
Missing response of mechanical system or
incorrect setting
– Machine goes into emergency shutdown
12
Red
K117 – Contact battery voltage
Control error (controller)
– Machine goes into emergency shutdown

Table of Contents

Related product manuals