8-26 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Hydraulic oil temperature monitoring (temperature sensor)
Loader unit
Error code FMI
Warning
light
Error description Remedy
517006
4 Yellow
B007: Signal range exceeded or short circuit to
machine ground/sensor ground
– Gear pump hydraulics only runs at minimum
revolutions
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
28 Yellow
B007: Open circuit or short circuit to positive
supply voltage
– Gear pump hydraulics only runs at minimum
revolutions
Error code FMI
Warning
light
Error description Remedy
517042
3 Yellow
B043 – Position sensor boom
Signal range exceeded or short circuit to positive
supply voltage
– Raising/lowering: no speed control possible
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
4 Yellow
B043 – Position sensor boom
Signal range fallen below or short circuit to vehicle
ground / sensor ground
– Raising/lowering: no speed control possible
28 Yellow
B043 – Position sensor of the boom
Open control circuit or short circuit to positive
supply voltage
– Raising/lowering: no speed control possible
517043
3 Yellow
B044 – Position sensor tilt ram:
Signal range exceeded or short circuit to
positive supply voltage
– Tilt in/tilt out: no speed control possible
4 Yellow
B044 – Position sensor tilt cylinder:
Signal range fallen below or short circuit to
vehicle ground/sensor ground
– Tilt in/tilt out: no speed control possible
28 Yellow
B044 – Position sensor tilt cylinder:
Open control circuits= or short circuit to positive
supply voltage
– Tilt in/tilt out: no speed control possible