Operation
7.10 Machine Monitoring
66
Operator’s Manual | LTV 4L/6L | 5100065071 | 02/2023 | [en-US]
5. Allow the engine to warm up before operating the lights.
Operating the lights
1. Turn on the main circuit breaker (1).
Fig.38: Starting, operating, and stopping controls
2. Turn on individual circuit breakers (3) one at a time.
Notes
• Metal halide floodlights require a warm-up time of 5–15minutes before
they reach full brightness.
• After turning the lights off, a cool-down time of 10minutes is necessary
before they can be turned on again.
Stopping the machine
NOTICE
Failure to turn off lights may cause damage to the electrical system.
► Turn off the lights before stopping the engine.
1. Disconnect all loads from the machine.
2. Turn the circuit breakers (1) off.
3. Press the Stop button (5) to de-energize the fuel solenoid.
7.10 Machine Monitoring
Engine and generator information is displayed on the LCD panel. The user
can scroll through the screens to monitor machine parameters.