EasyManuals Logo

Wacker Neuson LTV 4L User Manual

Wacker Neuson LTV 4L
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Operation
7.13 Auto Mode (Auto Start/Stop) (if equipped)
72
Operator’s Manual | LTV 4L/6L | 5100065071 | 02/2023 | [en-US]
Operator Editor Parameters for Auto Start by Location
901 Enable Scheduler (0) OFF, (1) ON (Must be ON for Location mode)
902 Schedule Bank A Period (0) Weekly, (1) Monthly, (2) Daily (Must be Daily for Location mode)
903 Auto Mode #1 Scheduler (0) = Scheduler, (1) = Location (1) Clears any Scheduler entries
904 Load Mode #1 Scheduler (0) Run, No-Lamps, (1) Run w-Lamps, (2) No Run, Lamp Op Only
Arrow down to 1001
1001 Time of Day 00:00:00 Hr:Mins:Sec (24 hr format) Preloaded for WI, CST zone
1002 Day of Month 1–31 Preloaded for WI, CST zone
1003 Month of Year 1–12 Preloaded for WI, CST zone
1004 Year 2020 (2000–2029) Preloaded for WI, CST zone
1005 Enable Daylight Savings (1) ON, (2) OFF
1006 Daylight Saving Offset 0:00 Hours:Minutes (+ 0:00 to + 2:00)
1007 Latitude (+N or -S of Equator) + 43.18° Decimal Degrees, Preloaded for WI, CST zone
1008 Longitude (+E or -W of Greenwich,
England)
- 88.09° Decimal Degrees, Preloaded for WI, CST zone
1009 Time Zone Offset (from Greenwich,
England)
- 6:00 Hrs (+E or -W of Greenwich), Preloaded for WI, CST zone
1010 Sunset Offset 0:00 Hours:Minutes (- 2:00 to + 2:00)
1011 Sunrise Offset 0:00 Hours:Minutes (- 2:00 to + 2:00)
Operator Editor Parameters for Auto Start by Scheduler
901 Enable Scheduler (0) OFF, (1) ON (Must be on for Scheduler mode)
902 Schedule Bank A Period (0) Weekly, (1) Monthly, (2) Daily ((2) Daily = Same every day)
903 Auto Mode #1 Scheduler (0) = Scheduler, (1) = Location ((1) Clears all Scheduler entries)
904 Load Mode #1 Scheduler (0) Run, No-Lamps, (1) Run w-Lamps, (2) No Run, Lamps Op Only
905 Start Time #1 Scheduler 00:00:00 Hr:Mins:Sec (24 hr format)
906 Start Day #1 Scheduler (1) M, (2) TU, (3) W, (4) TH, (5) FR, (6) SA, (7) SU
907 Start Week #1 Scheduler (1), (2), (3), (4) (2, 3, 4 are for Monthly mode only)
908 Run Duration #1 Scheduler 00:00:00 (Hrs:Mins:Sec)
909 Auto Mode #2 Scheduler (0) = Scheduler, (1) = Location ((1) Clears all Scheduler entries)
910 Load Mode #2 Scheduler (0) Run, No-Lamps, (1) Run w-Lamps, (2) No Run, Lamps Op Only
911 Start Time #2 Scheduler 00:00:00 (Hr:Mins:Sec, 24 hr format)
912 Start Day #2 Scheduler (1) M, (2) TU, (3) W, (4) TH, (5) FR, (6) SA, (7) SU
913 Start Week #2 Scheduler (1), (2), (3), (4) (2, 3, 4 are for Monthly mode only)
914 Run Duration #2 Scheduler 00:00:00 (Hrs:Mins:Sec)
915 Auto Mode #3 Scheduler (0) = Scheduler, (1) = Location ((1) Clears all Scheduler entries)
916 Load Mode #3 Scheduler (0) Run, No-Lamps, (1) Run w-Lamps, (2) No Run, Lamps Op Only
917 Start Time #3 Scheduler 00:00:00 (Hr:Mins:Sec, 24 hr format)
918 Start Day #3 Scheduler (1) M, (2) TU, (3) W, (4) TH, (5) FR, (6) SA, (7) SU
919 Start Week #3 Scheduler (1), (2), (3), (4) (2, 3, 4 are for Monthly mode only)
920 Run Duration #3 Scheduler 00:00:00 (Hrs:Mins:Sec)
921 Auto Mode #4 Scheduler (0) = Scheduler, (1) = Location ((1) Clears all Scheduler entries)
922 Load Mode #4 Scheduler (0) Run, No-Lamps, (1) Run w-Lamps, (2) No Run, Lamps Op Only