SPEEDGATE Installation and Maintenance Manual Revision 1 - MAY 2023
47
SPEEDGATE INSTALLATION
5. Ensure minimum of 4” (10cm) thread exposed above foundaon. See chemical anchor installaon
guide accompanying the product for depth of anchor holes. HILTI anchors and epoxy are available
from Wallace Perimeter Security.
The installer shall read and follow the manufacturer’s wrien instrucons for HILTI HVU2 1” X 8 1/4”
accompanying the shipped adhesive capsule product. Refer to step-by-step diagram on the following
pages, summarized below.
SUMMARY OF DIAGRAM STEPS 1 TO 11:
STEPS 1, 2, 3 As indicated in diagram on following pages. (Place each steel anchor bolt template on
the prepared, leveled foundaons and center the conduits.)
STEP 4 On both concrete piles:
Drill two (non-corner) 1/2” by 2 3/4” deep holes directly opposite one another into
the pre-drilled steel anchor bolt template.
STEP 5 On both concrete piles:
Insert two wedge anchors into the 1/2” by 2 3/4” deep holes.
STEP 6 On both concrete piles:
In the four corners of each pre-drilled steel anchor bolt template, drill 1 1/8” by 9”
deep holes.
STEP 7 On both concrete piles:
Use a hand-operated air pump in combinaon with a hole-cleaning brush to clean
debris and dust from each of the drill holes prior to anchor installaon.
On both concrete piles:
Check the seng depth in each of the 1 1/8” by 9” deep (four-corner) hammer-drilled
holes. Ensure minimum of 4” (10cm) thread is exposed above the foundaon.
STEP 8 On both concrete piles:
Insert the HILTI foil (mortar) capsule with the peak ahead (tapered end) to the back
of the hole.
STEP 9 Using 1” grade 8 anchor bolts (or equivalent), embed the anchors; drive with plugged
tool into the hole(s). A nut and washer shall be ghtened on each anchor bolt.
STEP 10, 11 8 ¼” is the minimum depth for driving the anchor into the hole. Refer to manufacturer’s
instrucons for appropriate curing me.