WIRE SIZES, TYPES AND LOCATIONS
The electrical connecons for a SpeedGate are as follows:
Table 6. SpeedGate Electrical Connecons References
1. Conduit Between Primary and Secondary Columns
Run through header between Columns 1 and 2 for PDTT
(TOP TRACK) Model; OR 2” underground conduit between
Columns 1 and 2 for PDXT (TRACKLESS) Model.
• [PDTT] “PDXT, PDXT-C and
PDTT Electrical Point-to-Point
Diagrams - 1” on page 59
• [PDXT] “PDXT, PDXT-C and
PDTT Electrical Point-to-Point
Diagrams - 2” on page 61
• [PDXT-C] “PDXT, PDXT-C and
PDTT Electrical Point-to-Point
Diagrams - 3” on page 63
1.1 Low voltage wiring to Post Terminaon Box, excluding the
encoder and motor cables:
The Post Terminaon Box is in the column that is located
nearest to the Operator Cabinet. All of the gate safety inputs
except for the vehicle detector loop leads terminate into the
Post Terminaon box. The mul-conductor low voltage cable
connects the Post Terminaon box to the operator cabinet.
All wires from the secondary column terminate into the Post
Terminaon box located in the Primary Column.
• “Post Terminaon Box” on
page 86
Figure 13. Locaon of Post Terminaon Box