Do you have a question about the WAVECONTROL SMP2 and is the answer not in the manual?
Brand | WAVECONTROL |
---|---|
Model | SMP2 |
Category | Measuring Instruments |
Language | English |
Ensuring sufficient battery charge and protecting the device from moisture.
Maintenance and repair must be performed by qualified personnel only.
Device requires calibration for proper operation; check calibration validity.
Instrument for measuring electromagnetic fields with a wide frequency range via probes.
Combines static, broadband, and selective (FFT) measurements with WPM.
Instructions for unpacking and verifying the equipment upon receipt.
Inspect packaging for damage and document any issues on the delivery note.
Description of the front panel interface: screen, keypad, and buttons.
Information on connecting and using field probes with the SMP2 device.
Details external connection options like USB and Fibre Optic.
Detailed instructions on how to switch the SMP2 device on and off.
Provides instantaneous and continuous information on the measured electromagnetic field.
Explanation of various icons displayed on the main screen.
Explains different measurement parameters like window time, sampling rate, etc.
The primary screen for accessing various sub-menus for configuration and data.
Access to change measurement parameters like time, interval, and averaging.
Access to view and manage stored measurements.
Access to modify general device settings like alarm, display, and sound.
Screen for configuring various measurement parameters like time, samples, and averaging.
Details configurable parameters including standards, measurement behavior, and post-processing.
Settings for broadband probes with correction factors, including enabling correction and limit values.
Displays all stored measurements, allowing navigation through pages.
Options to view, delete single measurements, or delete all memorized data.
View probe information, activate/deactivate calibration warning, configure 3rd party calibration.
Indicates how calibration expiry is visually signaled and options to handle it.
Allows modification of GPS parameters, similar to Measurement Options.
Selecting the desired format for displaying latitude and longitude coordinates.
Allows modification of general SMP2 parameters like alarm, display, sound, and device settings.
Configuration to activate/deactivate alarms, define thresholds, and set units.
Overview of available measurement modes like Time, FFT, and Frequency Log.
Detailed steps and considerations for performing time domain measurements.
Detailed explanation of FFT mode for selective probes and frequency analysis.
Automates measurements at different positions, displaying averages on a bar graph.
Information on the rechargeable Li-ion battery, operation time, and charge level check.
Step-by-step instructions for recharging the SMP2 battery.
Detailed instructions for installing the SMP2 Reader software on a PC.
Specifies the operating system, .NET Framework, and RAM needed for the software.
Instructions for initial software use, registration, and accessing updates.
Measurements load automatically when the SMP2 is connected via USB.
Shows tables and graphs of field samples when a measurement is selected.
Options for exporting, deleting measurements, and sending data to the control centre.
Access and download SMP2 screenshots associated with measurements.
Shows internal SMP2 information: firmware version, storage capacity, etc.
Click 'Export' on Measurements screen to download and export data to Excel files.
Report template location and possibility to customize it, including changing the logo.
Real-time display of measured data on PC via fibre optic connection, allowing setting changes.
Start/stop logging data and take screenshots directly from the live screen.
Instructions for updating the SMP2 Reader software via the Wavecontrol intranet.
Steps for updating the SMP2 device's firmware.
Instructions for cleaning the device and screen using a soft anti-static cloth.
Guidelines for handling the SMP2 and probes, protecting them from moisture and impacts.
Recommendation for recalibrating the SMP2 and probes every 2 years.
Issue: Red LED, no screen response. Resolution: Restart device; contact support if persists.
Issue: Menu returns to main screen. Resolution: Exit Live Measurement mode.
Issue: Low autonomy. Resolution: Recalibrate battery, consider replacement; contact support.
Details on measurement functions: probes, units, acquisition time, display, average types.
Details on probe interface, data download, firmware updates, and battery charger connection.
Overall specifications: battery, operation time, standby time, recharge time, temperature, size, weight.
Presents a table of available probes with their field, frequency, and measurement type.
SMP2 is ideal for analyzing electric and magnetic fields in public spaces and workplaces.
Table details common applications, field characteristics, frequency ranges, standards, and probe combinations.
Warning regarding connecting SMP2 directly to WPH-DC probe in high field conditions (use extension cable).
WPH-DC uses hall sensor technology; requires zeroing with 'zero Gauss' camera for accuracy.
Overview of SMP2 + WP400/WP400-3/WPH-DC for low frequency EMF assessment.
Explanation of the Weighted Peak Method (WPM) used for low frequency assessment.
WPM is appropriate for complex non-sinusoidal signals at low frequencies.
SMP2 offers an extensive list of limits from various standards for WPM measurements.
Communication protocol valid for USB or fibre, differing mainly in port settings.
Communication uses XML strings; SMP2 checks frames and rejects malformed ones.
Product complies with essential requirements of the 2004/108/EC EMC Directive.
Lists relevant standards and their descriptions related to product conformity.