WAVECONTROL SMP2 User Manual

WAVECONTROL SMP2
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
info@wavecontrol.com
www.wavecontrol.com
+34 93 320 80 55
Safety, Quality, Service
V 4.0
USER’S MANUAL
SMP2
Electromagnetic Field Meter
Question and Answer IconNeed help?

Do you have a question about the WAVECONTROL SMP2 and is the answer not in the manual?

WAVECONTROL SMP2 Specifications

General IconGeneral
BrandWAVECONTROL
ModelSMP2
CategoryMeasuring Instruments
LanguageEnglish

Summary

Warnings and Precautions

Battery and Handling Precautions

Ensuring sufficient battery charge and protecting the device from moisture.

Qualified Personnel for Maintenance

Maintenance and repair must be performed by qualified personnel only.

Calibration Requirements

Device requires calibration for proper operation; check calibration validity.

Introduction to the SMP2

SMP2 Device Overview

Instrument for measuring electromagnetic fields with a wide frequency range via probes.

Integrated Measurement Capabilities

Combines static, broadband, and selective (FFT) measurements with WPM.

First Steps: Unpacking and Setup

Unpacking and Equipment Check

Instructions for unpacking and verifying the equipment upon receipt.

Packaging Inspection Upon Receipt

Inspect packaging for damage and document any issues on the delivery note.

Getting Started with the SMP2

Front Panel Overview

Description of the front panel interface: screen, keypad, and buttons.

Field Probe Compatibility

Information on connecting and using field probes with the SMP2 device.

External Connection Ports

Details external connection options like USB and Fibre Optic.

SMP2 Initial Use

Powering the SMP2 On and Off

Detailed instructions on how to switch the SMP2 device on and off.

Main Screen Interface

Main Screen Information Display

Provides instantaneous and continuous information on the measured electromagnetic field.

Main Screen Icons Guide

Explanation of various icons displayed on the main screen.

Measurement Information Details

Explains different measurement parameters like window time, sampling rate, etc.

Menu Screen Navigation

Menu Screen Navigation

The primary screen for accessing various sub-menus for configuration and data.

Measurement Options Menu

Access to change measurement parameters like time, interval, and averaging.

Measurement Log Menu

Access to view and manage stored measurements.

General Settings Menu

Access to modify general device settings like alarm, display, and sound.

Measurement Options Configuration

Measurement Configuration Screen

Screen for configuring various measurement parameters like time, samples, and averaging.

Configurable Measurement Parameters

Details configurable parameters including standards, measurement behavior, and post-processing.

Post-Processing Settings

Settings for broadband probes with correction factors, including enabling correction and limit values.

Measurement Log Management

Measurement Log Display

Displays all stored measurements, allowing navigation through pages.

Measurement Log Actions

Options to view, delete single measurements, or delete all memorized data.

Probe Information and Calibration

Probe Information and Calibration Status

View probe information, activate/deactivate calibration warning, configure 3rd party calibration.

Probe Calibration Expiry Warning

Indicates how calibration expiry is visually signaled and options to handle it.

GPS Configuration

GPS Configuration Screen

Allows modification of GPS parameters, similar to Measurement Options.

GPS Coordinate Format Selection

Selecting the desired format for displaying latitude and longitude coordinates.

General Settings

General Settings Configuration

Allows modification of general SMP2 parameters like alarm, display, sound, and device settings.

Alarm Function Settings

Configuration to activate/deactivate alarms, define thresholds, and set units.

SMP2 Functions

Measurement Modes Selection

Overview of available measurement modes like Time, FFT, and Frequency Log.

Time Domain Measurement Procedure

Detailed steps and considerations for performing time domain measurements.

FFT Mode for Frequency Domain Analysis

Detailed explanation of FFT mode for selective probes and frequency analysis.

Spatial Averaging Measurements

Automates measurements at different positions, displaying averages on a bar graph.

Battery Information and Charging

General Battery Information

Information on the rechargeable Li-ion battery, operation time, and charge level check.

Battery Recharging Procedure

Step-by-step instructions for recharging the SMP2 battery.

SMP2 Reader Software

SMP2 Reader Software Installation

Detailed instructions for installing the SMP2 Reader software on a PC.

SMP2 Reader System Requirements

Specifies the operating system, .NET Framework, and RAM needed for the software.

Using the SMP2 Reader Software

Instructions for initial software use, registration, and accessing updates.

Software Measurements Screen

Automatic Measurement Loading

Measurements load automatically when the SMP2 is connected via USB.

Measurement Detail View

Shows tables and graphs of field samples when a measurement is selected.

Measurement Screen Export and Management Options

Options for exporting, deleting measurements, and sending data to the control centre.

Software Screenshots Management

Displaying and Downloading Screenshots

Access and download SMP2 screenshots associated with measurements.

Software Information and Export

SMP2 Internal Information Display

Shows internal SMP2 information: firmware version, storage capacity, etc.

Exporting Measurements to Excel

Click 'Export' on Measurements screen to download and export data to Excel files.

Export Report Template Location and Customization

Report template location and possibility to customize it, including changing the logo.

Live Measurements via PC

Live Measurement PC Display

Real-time display of measured data on PC via fibre optic connection, allowing setting changes.

Live Screen: Logging and Screenshots

Start/stop logging data and take screenshots directly from the live screen.

Software and Firmware Updates

Updating SMP2 Reader PC Software

Instructions for updating the SMP2 Reader software via the Wavecontrol intranet.

Updating SMP2 Firmware

Steps for updating the SMP2 device's firmware.

Maintenance Procedures

Cleaning the Device and Screen

Instructions for cleaning the device and screen using a soft anti-static cloth.

Handling the SMP2 and Probes

Guidelines for handling the SMP2 and probes, protecting them from moisture and impacts.

Regular Recalibration Recommendations

Recommendation for recalibrating the SMP2 and probes every 2 years.

Troubleshooting Common Issues

Troubleshooting: No Screen Response on Power On

Issue: Red LED, no screen response. Resolution: Restart device; contact support if persists.

Troubleshooting: Menu Access Failure

Issue: Menu returns to main screen. Resolution: Exit Live Measurement mode.

Troubleshooting: Low Battery Autonomy

Issue: Low autonomy. Resolution: Recalibrate battery, consider replacement; contact support.

Technical Specifications

SMP2 Measurement Functions

Details on measurement functions: probes, units, acquisition time, display, average types.

SMP2 Interface Specifications

Details on probe interface, data download, firmware updates, and battery charger connection.

General SMP2 Specifications

Overall specifications: battery, operation time, standby time, recharge time, temperature, size, weight.

Available Probes Overview

List of Available Probes

Presents a table of available probes with their field, frequency, and measurement type.

Common Applications and Standards

SMP2 Application Suitability

SMP2 is ideal for analyzing electric and magnetic fields in public spaces and workplaces.

Common EMF Exposure Applications

Table details common applications, field characteristics, frequency ranges, standards, and probe combinations.

Static Field Measurements with WPH-DC

WPH-DC Probe Warning

Warning regarding connecting SMP2 directly to WPH-DC probe in high field conditions (use extension cable).

WPH-DC Probe Hall Sensor Technology

WPH-DC uses hall sensor technology; requires zeroing with 'zero Gauss' camera for accuracy.

Low Frequency Assessment Methods

Introduction to Low Frequency Assessment

Overview of SMP2 + WP400/WP400-3/WPH-DC for low frequency EMF assessment.

Weighted Peak Method (WPM)

Explanation of the Weighted Peak Method (WPM) used for low frequency assessment.

Weighted Peak Method (WPM) Application

Introduction to Weighted Peak Method (WPM)

WPM is appropriate for complex non-sinusoidal signals at low frequencies.

SMP2 Limits for WPM

SMP2 offers an extensive list of limits from various standards for WPM measurements.

Communication Protocol

Communication Protocol Overview

Communication protocol valid for USB or fibre, differing mainly in port settings.

Command and Response Format (XML)

Communication uses XML strings; SMP2 checks frames and rejects malformed ones.

Declaration of Conformity (DoC)

EMC Directive Compliance Statement

Product complies with essential requirements of the 2004/108/EC EMC Directive.

Relevant Standards and Descriptions

Lists relevant standards and their descriptions related to product conformity.

Related product manuals