38 | CFW500
Troubleshooting and Maintenance
English
6.3 DATA TO CONTACT THE TECHNICAL ASSISTANCE
For information or service request, it is important to have at hand the following data:
Inverter model.
Serial number and manufacturing date of the product identification label (refer to Section 2.4
IDENTIFICATION LABELS on page 10).
Software version installed (see P0023 and P0024).
Information about the application and programming executed.
6.4 PREVENTIVE MAINTENANCE
DANGER!
Always disconnect the general power supply before changing any electric
component associated to the inverter.
High voltages can be present even after the disconnection of the power supply.
Wait for at least ten minutes for the full discharge of the power capacitors.
Always connect the frame size of the equipment to the protection grounding
(PE) at the proper point for that.
DANGER!
branchez toujours l'alimentation principale avant d'entrer en contact avec
un appareil électrique associé au variateur.
Des tensions élevées peuvent encore être présentes, même après déconnexion
de l’alimentation. Pour éviter les risques d’électrocution, attendre au moins 10
minutes après avoir coupé l’alimentation d’entrée pour que les condensateurs
de puissance soient totalement déchargées. Raccordez toujours la masse de
l'appareil à une terre protectrice (PE). Utiliser la borne de connexion adéquate
du variateur.
ATTENTION!
The electronic cards have components sensitive to electrostatic discharges.
Do not touch directly on the components or connectors. If necessary, first touch
the grounded metallic frame size or use proper grounding strap.
Do not execute any applied potential test on the inverter!
If necessary, contact WEG.
When installed in proper environment and operating conditions, the inverters require little service.
Table 6.2 on page 39 lists the main procedures and intervals for routine maintenance. Table
6.3 on page 39 suggests inspections on the product every 6 months after startup.