How to fix 'Paper Jam' error on Welch Allyn CP 100 Medical Equipment?
- MmarshnormaSep 10, 2025
If the Welch Allyn Medical Equipment displays “Paper Jam”, reload the paper. This issue is usually caused by paper loaded incorrectly.

How to fix 'Paper Jam' error on Welch Allyn CP 100 Medical Equipment?
If the Welch Allyn Medical Equipment displays “Paper Jam”, reload the paper. This issue is usually caused by paper loaded incorrectly.
Why is there a wandering baseline on my Welch Allyn CP 100 Medical Equipment?
If you observe a wandering baseline (an upward and downward fluctuation of the waveforms) on your Welch Allyn Medical Equipment, it could be due to several factors. Try these steps: * Clean the patient's skin with alcohol or acetone, especially if electrodes are dirty, corroded, loose, or positioned on a bony area. * Reposition or replace the electrodes if there is insufficient or dried electrode gel. * Help the patient relax, as oily skin or body lotions can interfere. * If wandering baseline persists due to rapid or apprehensive breathing, refer to the CP 200 or CP 100 Directions for Use Manual for instructions on turning on the baseline filter.
How to fix muscle tremor interference on Welch Allyn CP 100?
If you're experiencing muscle tremor interference (random, irregular voltage superimposed on the waveforms) on your Welch Allyn Medical Equipment, which may resemble AC interference, consider the following: 1. Help the patient get comfortable if they are tense or nervous. 2. Ensure the patient is warm to prevent shivering. 3. Check all electrode contacts. 4. Make sure the exam bed is wide or long enough to support arms and legs comfortably. If the issue continues, consult the CP 200 or CP 100 Directions for Use Manual for instructions on turning on the muscle-tremor filter. If interference still persists, the problem is probably electrical in nature; refer to the manual for reducing AC interference.
How to troubleshoot AC interference on Welch Allyn CP 100?
To resolve AC interference, check all electrode contacts and lead wires. Ensure the patient isn't touching any metal and that the AC power cable isn't touching the patient lead cable. Verify the correct AC filter is selected. If the problem continues, unplug the Welch Allyn Medical Equipment from AC power and run it on battery. If this fixes the issue, the noise is from the power line. If it persists, the noise may be from other equipment or poorly grounded power lines; try moving to another room. Dirty, corroded, or loose electrodes, insufficient electrode gel, a patient touching metal, broken wires, nearby electrical devices, or incorrect AC filter settings can cause AC interference.
What to do if a dot is flashing on the Lead Status screen of Welch Allyn CP 100 Medical Equipment?
If a dot is flashing on the Lead Status screen, lead-off information is displayed, or one or more leads prints as a square wave, it could be due to poor electrode contact or a loose lead. Try reattaching the lead, replacing the electrode, and ensuring the electrode area is properly prepared by shaving, cleaning with alcohol or acetone, and allowing it to dry. Also, make sure the electrodes have been stored and handled correctly.
What to do if Welch Allyn Medical Equipment won't turn on when unplugged?
If your Welch Allyn Medical Equipment won't turn on when unplugged from AC power, check the battery connections and replace if necessary. Recharge the battery, or replace the battery fuse. The cause might be a disconnected or incorrectly connected battery, a low or bad battery, or a blown battery fuse.
What to do if Welch Allyn Medical Equipment shows 'Temperature Error'?
If the Welch Allyn Medical Equipment displays “Temperature Error”, allow it to cool, then try again. This error indicates that the printer head temperature is too high.
What to do if Welch Allyn CP 100 is unresponsive?
If your Welch Allyn Medical Equipment is unresponsive for an extended time, press the reset button using a small object like a paper clip. This usually happens when the system is frozen.
What does 'Out Of Paper' mean on Welch Allyn CP 100?
If the Welch Allyn Medical Equipment displays “Out Of Paper”, load paper and close the printer door. This message appears when the printer is out of paper or the printer door is open.
Why does my Welch Allyn CP 100 Medical Equipment shut down during printing?
If the Welch Allyn Medical Equipment shuts down during printing, recharge or replace the battery. This issue is caused by a low or bad battery.
| Category | Medical Equipment |
|---|---|
| Model | CP 100 |
| Brand | Welch Allyn |
| ECG Channels | 3-Channel |
| Display Type | LCD |
| Connectivity | USB |
| Weight | 1.5 kg |
| Cuff Compatibility | Not applicable |
| Measurements | Heart Rate |
| Printing | Thermal |
| Power Source | AC and Rechargeable Battery |
| Memory | 100 ECG records |
Overview of the safety summary and warnings for users.
Explanation of documentation, shipping, and certification symbols.
Important safety warnings applicable to general electrocardiograph use.
Precautions for handling static-sensitive electronic components.
General precautions for operating and maintaining the electrocardiograph.
Defines the manual's scope and reference for service procedures.
Details warranty and non-warranty service options.
Lists model numbers and their corresponding configurations.
Outlines recommended periodic maintenance schedules.
Describes the physical controls, indicators, and connectors.
Illustrates the navigation structure for system settings.
Explains the main menu structure and options.
Provides instructions on navigating through the device menus.
Guides on how to access and view device information.
Introduction to accessing device service menus.
Overview of the complete functional test procedure.
Procedure for performing a comprehensive functional checkout.
Lists necessary equipment for functional verification.
Form for tracking and recording validation test progress.
Guidance and tables for diagnosing and resolving common issues.
Details the warranty terms and conditions for the product.
Outlines procedures and policies for product service and repair.
Overview of disassembly and board removal procedures.
Information on identifying and handling screws during disassembly.
Recommended torque specifications for screws and nuts.
Step-by-step instructions for disassembling the unit.
Guide for ordering parts for the CP 100 and CP 200 Electrocardiographs.
Lists miscellaneous parts and their quantities.
Details on dimensions, weight, keyboard, paper, and printer.
Covers ECG settings, storage, frequency, sampling, power, and fuses.
Guidance on electromagnetic emissions and compliance.
Guidance on electromagnetic immunity and compliance.
Steps for updating the device software via SD card.
Steps to confirm the software update was successful.
Wiring diagram for the CP 200 model.
Wiring diagram for the CP 100 model.