120 03/2016 UM-MT-EN-01
ATTENTION
If there are defects or deviations in the control function, notify WOODWAY
Customer Service immediately.
The device must be taken out of service and disabled until repaired. Repairs
may only be carried out by trained and authorized personnel.
Before starting any maintenance, remove the side panels (NOT electronics covers).
Preventative maintenance consists of the following measures:
Clean the inside of the treadmill with a vacuum cleaner. Do not touch the electrical
components (cables, transformers, connectors, etc.).
Visually check the drive unit toothed belt (drive belt) for cracks and other wear and
missing or broken teeth.
Inspect the aluminum profiles of the slats for damage.
Visually inspect all mechanical components for damage (lifting mechanism, welded
frame, side panels, treadmill feet, rollers on the lifting scissors, railings, display,
emergency stop mushroom, emergency stop magnetic switch).
In rare cases there may be bearing damage. Under certain circumstances this can be
detected through excessive grease leakage from the bearing housing.
Have the time limits prescribed by the manufacturer for the maintenance and safety
checks been complied with?
A repair must take place in the following situations:
Liquid has gotten into the device
Damaged power cord (cable, plug)
Defective drive system toothed belt
Suspected bearing damage
Suspected/established device defect
Bucking, sudden stopping, or accelerating of the running surface
Button(s) fail to function
Burning smell, smoke, or unusual noises
Malfunction (failure) of the emergency stop button
Malfunction (failure) of the emergency stop magnet
Damage to the running surface belt
All other defects which may affect the safety of the device
Semi-Annual Maintenance
Vacuum inside the treadmill (unplug device and remove side covers).
Inspect all nuts and bolts. Tighten if necessary.
Clean running surface and spray with anti-static spray.
Check drive belt (replace if shredding or if teeth are missing).
Annual Maintenance
A complete function test of the treadmill must be carried out every 2 - 4 weeks depend-
ing on the duration and intensity of use.
The proper maintenance of the treadmill must take place annually in conjunction with
the Technical Safety Checks (TSC).
In exceptional cases, the maintenance interval may be adapted to the extended inspec-
tion intervals in accordance with Technical Safety Checks (TSC). Maintenance and repairs
may only be carried out by trained and authorized personnel.