03/2016 – UM-MT-EN-01 123
Fig. 117 Lubrication, incline system
1. Incline toothed rack
2. Incline chain
Note: Use a minimal amount of lubricant to prevent excess dirt and debris from sticking
to the device after cleaning.
9.4 Adjusting and Calibrating
WOODWAY treadmills use an incline system with a toothed rack and gear drive. For sys-
tems with an incline of 15% to 25% similar components are used; they differ with re-
spect to the movement of the toothed rack.
Inspect/tighten all hardware. Replace any hardware that is stripped or missing. Inspect
the handrail clamps for damage (e.g. cracks).
Remove 2 running belt slats to access the bearing rail assemblies. Clean the bearing rails
and replace any bearings that are causing noise or that do not spin freely.
Required tools: 2 ft. level
When the treadmill wobbles or seems unstable, the support feet must be checked. Check
both ends of the treadmill with a level. See Section 6.3.1
Note: When the treadmill is moved, the frame may bend. If the treadmill seems to wob-
ble, press down on the railing on either side. This can realign the railing without making
a support foot adjustment necessary.