EasyManua.ls Logo

Woodway PATH - Adjusting, Calibrating, Disabling, Fuses

Woodway PATH
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03/2016 UM-MT-EN-01 123
Fig. 117 Lubrication, incline system
1. Incline toothed rack
2. Incline chain
Note: Use a minimal amount of lubricant to prevent excess dirt and debris from sticking
to the device after cleaning.
9.4 Adjusting and Calibrating
WOODWAY treadmills use an incline system with a toothed rack and gear drive. For sys-
tems with an incline of 15% to 25% similar components are used; they differ with re-
spect to the movement of the toothed rack.
Inspect/tighten all hardware. Replace any hardware that is stripped or missing. Inspect
the handrail clamps for damage (e.g. cracks).
Remove 2 running belt slats to access the bearing rail assemblies. Clean the bearing rails
and replace any bearings that are causing noise or that do not spin freely.
Required tools: 2 ft. level
When the treadmill wobbles or seems unstable, the support feet must be checked. Check
both ends of the treadmill with a level. See Section 6.3.1
Note: When the treadmill is moved, the frame may bend. If the treadmill seems to wob-
ble, press down on the railing on either side. This can realign the railing without making
a support foot adjustment necessary.
Incline System
Handrails
Bearing Rails
Treadmill Feet
1
2

Table of Contents