219
(1-8-1, even parity)
(1-8-1, no parity)
Appendix B-3-2. Communication data structure
RTU mode
Keep no input signal at least 10ms
Communication address: 8-bit binary address
Function code: 8-bit binary address
Data content: N*8-bit data, N<=8, max 8 bytes
16-bit CRC parity code is composed of two 8-bit binary
Keep no IO signal at least 10ms
Communication address
00H: all frequency converter broadcast
01H: communicate with 01 address inverter.
0FH: communication with 15 address inverter.
10H: communication with 16 address inverter. And so on... , up to 254 (FEH).
Function code and data
Read the contents of registers, read multiple registers, but not more than 12 at a
time, each time can only read the same group of data
Write data into the register
(1) Function code 03H: read register
For example, read the register address 7000H (operation frequency).
RTU mode
Format of inquiry information
Format of response information