68
Group P7: Fault parameters
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
P7-72
Integral coefficient of instantaneous
stop non-stop
0 ~ 100
30
0748H
P7-73
Deceleration time of instantaneous
stop non-stop
0 ~ 300.0s
20.0
×
0749H
Group P8: Keyboard and display
Group P8: Keyboard and display
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
P8-00
JOG/REV function
selection
0: Menu switching
1: Forward and reverse switching
2: Forward jog
3: Reverse jog
0
×
0800H
P8-01
STOP/REST function
0: Only in keyboard operation mode,
STOP/REST key shutdown function is
effective
1: In any operation mode, STOP/REST key
is effective
1
0801H
P8-02
Parameter initialization
0: No operation
1: Restore factory parameters, excluding
motor parameters (in 3730 and above
versions, P0-13 and P0-15 do not restore
factory values)
2: Clear record information
3: Restore factory parameters (including
motor parameters)
4: Backup current user parameters (only
supported by LCD panel)
5: Restore user backup parameters (only
supported by LCD panel)
0
×
0802H
P8-03
User password
0~65535
00000
-
P8-05
Personalized parameter
mode selection
Ones bit:
0: No display
1: Display user selected parameters
Tens bit:
0: No display
1: Display user modified parameters
00
×
-
P8-06
Parameter modification
attribute
0: Modifiable
1: Not modifiable
0
-
P8-07
LED operation display
parameter 1 (Low bit)
The bit meaning
Bit0: Operating frequency
Bit1: The set frequency
001F
0807H