81
Group A0: textile
Parameter
Name
Setting range
Default value
Modify
Modbus
address
swing frequency
Group A1: Virtual IO
Group A1: Virtual IO
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
A1-00
Function selection of virtual
X1 terminal
0~51: See group P2 physical X input selection
00
×
A100H
A1-01
Function selection of virtual
X2 terminal
00
×
A101H
A1-02
Function selection of virtual
X3 terminal
00
×
A102H
A1-03
Function selection of virtual
X4 terminal
00
×
A103H
A1-04
Function selection of virtual
X5 terminal
00
×
A104H
A1-05
Virtual X terminal effective
state source
Ones bit: virtual X1
0: The state of virtual Y1 determines whether
virtual X1 is valid
1: Function code A1-06 sets whether virtual
X1 is valid
Tens bit: virtual X2
Hundreds bit: virtual X3
Thousands bit: virtual X4
Ten thousands bit: virtual X5
00000
×
A105H
A1-06
Virtual X terminal status
setting
0: Invalid
1: Valid
Tens bit: virtual X1
Tens bit: virtual X2
Hundreds bit: virtual X3
Thousands bit: virtual X4
Ten thousands bit: virtual X5
00000
×
A106H
A1-07
Function selection of AI1
terminal as X terminal
0~51
00
×
A107H
A1-08
Function selection of AI2
terminal as X terminal
0~51
00
×
A108H
A1-10
Selection of effective mode
when AI is used as X
terminal
Ones bit: AI1
Tens bit: AI2
0: High level valid
1: Low level valid
000
×
A10A
H
A1-11
Virtual Y1 output function
selection
0: connect with physical X1 inside
1~42: See group P3 physical Y output
00
A10BH