70
Group P8: Keyboard and display
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
Bit10: PLC Step
Bit11: Counting value
Bit12: Length value
P8-10
Accumulated running time
0h~65535h
-
-
080AH
P8-11
Cumulative power on time
0h~65535h
-
-
080BH
P8-12
Cumulative power
consumption
0~65535 degree
-
-
080CH
P8-15
Software version
-
-
-
080FH
P8-16
Firmware version
-
-
-
0810H
P8-19
Inverter module radiator
temperature
0.0~100.0
-
-
0813H
P8-20
Output power factor
0.00% ~ 200.0%
100.0
0814H
P8-21
Load speed display factor
0.0001~6.5000
1.0000
0815H
P8-22
Number of decimal points
for load speed display
Ones bit:number of decimal points of U0-16
0: 0 decimal places
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
Tens bit:number of decimal points of
U0-17,U0-18
1: 1 decimal place
2: 2 decimal places
11
0816H
Group P9: Communication parameters
Group P9: Communication parameters
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
P9-00
Serial communication
protocol selection
0: Modbus-RTU protocol
1: Extension card(Ethercat, CANopen)
0
×
0900H
P9-01
Local address
0: Broadcast address
1 ~ 247 (Modbus valid)
1
0901H
P9-02
Communication baud rate
Ones bit: MODBUS
0: 300BPS
1: 600BPS
2: 1200BPS
3: 2400BPS
4: 4800BPS
5: 9600BPS
6: 19200BPS
7: 38400BPS
Tens bit: EtherCAT/CANopen
06
0902H

Table of Contents