EasyManua.ls Logo

Xinje VH6 Series - Group P6: Vector Control Parameters

Xinje VH6 Series
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
Group P5: VF parameters
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
independently
1: When the voltage decreases to
zero, the frequency begins to
decrease again
P5-14
VF slip compensation gain
0.0%~200.0%
0.0%
050EH
P5-15
Slip compensation time constant
0.1~10.0s
0.0%
050FH
P5-16
VF over excitation gain
0~200
64
0510H
P5-17
VF oscillation suppression gain
0~100
Model
setting
0511H
P5-18
VF oscillation suppression mode
selection
0~4
3
×
0512H
P5-19
VF over current stall action
current
50~200%
150%
×
0513H
P5-20
VF over current stall suppression
enable
0: invalid
1: valid
1
×
0514H
P5-21
VF over current stall suppression
gain
0~100
20
0515H
P5-22
VF over current stall action
current compensation coefficient
50%~200%
50
×
0516H
P5-23
Overvoltage stall action voltage
200.0V~2000.0V
Model
setting
×
0517H
P5-24
Overvoltage stall enable
0: Invalid
1: Valid
1
×
0518H
P5-25
Over voltage stall suppression
frequency gain
0~100
30
0519H
P5-26
Over voltage stall suppression
voltage gain
0~100
30
051AH
P5-27
Limit of maximum rise frequency
of over voltage stall
0~50Hz
5Hz
×
051BH
Group P6: Vector control parameters
Group P6: Vector control parameters
Parameter
Name
Setting range
Default value
Modify
Modbus
address
P6-00
Speed loop proportional gain 1
1~100
30
0600H
P6-01
Speed loop integration time 1
0.01s~10.00s
0.50s
0601H
P6-02
Speed loop proportional gain 2
1~100
20
0602H
P6-03
Speed loop integration time 2
0.01s~10.00s
1.00s
0603H
P6-04
Switching frequency 1
0.00~P6-05
5.00Hz
0604H
P6-05
Switching frequency 2
P6-04~ P0-13
10.00Hz
0605H
P6-06
Integral attribute of speed loop
Ones bit: integral separation
0: invalid
0
0606H

Table of Contents