30
Button
Name
Function
REST
JOG/REV
ENT/DATA
MENU/ESC
STOP
RUN
79.6
89
Decrease
Decrease the value or pause frequency in operation
REST
JOG/REV
ENT/DATA
MENU/ESC
STOP
RUN
79.6
89
Shift/monitor
In the editing state, you can choose to set the modification bit of the data;
in other states, you can switch the display state and monitor parameters
3-1-3. LED lights
There are 5-digit 7-segment LED digital tubes and 4 status indicators on the inverter operation panel.
The four status indicators are located above the LED tube, from left to right: RUN, FWD/REV,
LOCAL/REMOT, TUNE. The following table describes the indicator lights.
Indicator lights
Meaning
Function
RUN
Operation indicator
ON: running
OFF: stop
FWD/REV
Forward/reverse
operation indicator
ON: reverse operation
OFF: forward operation
Flashing: status switching
LOCAL/REMOT
Command source
indicator
OFF: panel start/stop
ON: terminal start/stop
Flashing: communication start/stop
TUNE
Tuning indicator
Flash slowly: tuning status
Flash quickly: fault status
ON: torque status
3-1-4. Operation method
Through the operation panel, the inverter can be operated in various ways, for example:
(1) Parameter display and switch
Method 1:
Press button, switch LED display parameter, set running display parameter P8-07 and P8-08, set stop display
parameter P8-09.
When checking status monitoring parameters, you can press ENT/DATA key to switch back to the default
display status of monitoring parameters. The default monitoring parameter of shutdown state is the setting
frequency, and the default monitoring parameter of operation state is output frequency.
Method 2:
Check group U0 parameters, for example, U0-02.