82
Group A1: Virtual IO
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
selection
A1-12
Virtual Y2 output function
selection
0: connect with physical X2 inside
1~42: See group P3 physical Y output
selection
00
A10CH
A1-13
Virtual Y3 output function
selection
0: connect with physical X3 inside
1~42: See group P3 physical Y output
selection
00
A10D
H
A1-14
Virtual Y4 output function
selection
0: connect with physical X4 inside
1~42:See group P3 physical Y output
selection
00
A10EH
A1-15
Virtual Y5 output function
selection
0: connect with physical X5 inside
1~42:See group P3 physical Y output
selection
00
A10FH
A1-16
Virtual Y1 output delay time
0.0s ~ 3600.0s
0.0s
A110H
A1-17
Virtual Y2 output delay time
0.0s ~ 3600.0s
0.0s
A111H
A1-18
Virtual Y3 output delay time
0.0s ~ 3600.0s
0.0s
A112H
A1-19
Virtual Y4 output delay time
0.0s ~ 3600.0s
0.0s
A113H
A1-20
Virtual Y5 output delay time
0.0s ~ 3600.0s
0.0s
A114H
A1-21
Virtual Y terminal effective
state selection
Ones bit: virtual Y1
0: Positive logic
1: Negative logic
Tens bit: virtual Y2
Hundreds bit: virtual Y3
Thousands bit: virtual Y4
Ten thousands bit: virtual Y5
00000
A115H
Group A2: Second motor parameters
Group A2: Second motor parameters
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
A2-00
Motor type selection
0: Common asynchronous motor
0
×
A200H
A2-01
Motor rated power
0.1KW~650.0KW
Model
setting
×
A201H
A2-02
Motor rated voltage
1V~1200V
Model
setting
×
A202H
A2-03
Motor rated current
0.01A~655.35A (VFD power ≤55kW)
0.1A~6553.5A (VFD power >55kW)
Model
setting
×
A203H
A2-04
Motor rated frequency
0.01Hz~max output frequency
Model
setting
×
A204H
A2-05
Motor rated speed
1rpm~65535rpm
Model
setting
×
A205H