43
swing function can improve the evenness of the spindle winding. The relevant parameters are as follows:
Swing frequency setting mode
0: relative to center frequency 1: relative to the max
frequency
Swing frequency amplitude
Triangular rise time of swing frequency
The reference value of swing amplitude is determined by parameter A0-05.
0: relative to the center frequency (P0-05 frequency source), variable swing system. The swing varies with the
center frequency (set frequency).
1: relative to the maximum frequency (P0-13) is a fixed swing amplitude system.
When the swing frequency is relative to the center frequency (A0-05 = 0), the trajectory on the time axis is
shown as follows:
A0-06 swing amplitude AW:
When swing amplitude is relative to the center frequency (A0-05=0), AW= frequency source P0-05×A0-06;
When swing amplitude is relative to the max frequency (A0-05=1), AW=max frequency P0-13 × A0-06.
A0-08 swing frequency period: time value of a complete frequency swing period.
A0-07 Jump frequency amplitude:
The jump frequency amplitude is the percentage of the jump frequency relative to the swing amplitude when the
swing frequency is running, that is, the jump frequency = swing amplitude AW × jump frequency amplitude
A0-07.