4 Specifications and External Dimensions for Σ-V-SD Drivers
4.2.2 External Dimensions
4-14
Model: CACR-JU065ACA, -JU033DCA
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
Model: CACR-JU084ACA, -JU102ACA, -JU042DCA, -JU051DCA
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
338
380
55
±
0.510
5 65
75
15.5
7.5
380
7.5
(10)
55
75
10
(7.5)
365
(23)
(145)
(115
°
)
(135
°
)
300
200
5
(100)
23 334
5
63
(7)
4-M5 Screw Holes
Through Hole
SERVOPACK
Rear View
365
±
0.5 (Mounting Pitch)
Mounting Hole Diagram
(Mounting Pitch)
4-6 Dia.
Ground
Terminal
M4 Screws
Model
Number
Input Voltage
Nameplate
Cooling Fan
Heat Sink
Air Flow
Air Flow
Unit: mm
Approx. Mass: 6.4 kg
338
365
±
0.5
130
±
0.5
10
5
140
150
15.5
7.5
380
7.5
(10)
130
150
10
(7.5)
365
(145)
300
200
5
(100)
23
334136
7
(23)(7)
(115
°
)
(135
°
)
4-M5 Screw Holes
SERVOPACK
Rear View
Through Hole
(Mounting Pitch)
380
Mounting Hole Diagram
(Mounting Pitch)
Model
Number
Nameplate
Input Voltage
4-6 Dia.
Ground Terminal
M5 Screws
Cooling Fan
Heat Sink
Air Flow
Air Flow
Unit: mm
Approx. Mass: 11.8 kg

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CACR-JU series and is the answer not in the manual?

YASKAWA CACR-JU series Specifications

General IconGeneral
BrandYASKAWA
ModelCACR-JU series
CategoryServo Drives
LanguageEnglish

Related product manuals