3.2 Operating Procedures for Utility Functions
3.2.42 INDEXER Parameter Setting Initialization (FnB0B)
3-133
• The RES command must not being executed.
Operating Procedure
* If the key is pressed in an operation prohibited state, “Error.” is displayed for
approximately 2 seconds and then the display returns to the FnB0B operation screen.
In this case, make the setting again by referring to Preparation on page 3-132.
Step Operation Result
1
Press the key to open the Util-
ity Function Mode main menu, and
move the cursor with the
keys to select FnB0B.
2
Press the key to view the
FnB0B operation screen.
3
Press the key to start initializa-
tion of the parameters.*
Do not turn off the control power
supply until initialization has been
completed normally.
To cancel the FnB0B operation,
press the key before pressing
the key. The display returns to
the Utility Function Mode main
menu without executing the opera-
tion.
4
When parameter initialization has
been completed normally, “Done.”
is displayed.
5
Press the key to return to the
Utility Function Mode main menu.
6
To bring the settings into effect, turn the SERVOPACK power supply off
and back on.