11.4 Parameter Recording Table
11-31
Pn502
20 min
-1
Rotation Detection Level Immediately
Pn503
10 min
-1
Speed Coincidence Signal Output
Width
Immediately
Pn504 7 reference
units
NEAR Signal Width Immediately
Pn505 1024
reference
units
Overflow Level Immediately
Pn506 0 ms Brake Reference-Servo OFF Delay
Time
Immediately
Pn507
100 min
-1
Brake Reference Output Speed Level Immediately
Pn508 500 ms Timing for Brake Reference Output
during Motor Operation
Immediately
Pn509 20 ms Momentary Hold Time Immediately
Pn50A 2100 Input Signal Selections 1 After restart
Pn50B 6543 Input Signal Selections 2 After restart
Pn50C 8888 Input Signal Selections 3 After restart
Pn50D 8888 Input Signal Selections 4 After restart
Pn50E 3211 Output Signal Selections 1 After restart
Pn50F 0000 Output Signal Selections 2 After restart
Pn510 0000 Output Signal Selections 3 After restart
Pn511 8888 Reserved (Do not change) Immediately
Pn512 0000 Output Signal Reversal Settings After restart
Pn513 0088 Input Signal Selections After restart
Pn51A 0
reference
units
Position Error Level Between Motor
and Load
Immediately
Pn51B 100
reference
units
Reserved (Do not change) Immediately
Pn51C
450 min
-1
Reserved (Do not change) Immediately
Pn51D 0% Excessive Position Error Warning
Level
Immediately
Pn600 0 W Regenerative Resistor Capacity After restart
Pn601 0 W Reserved (Do not change) After restart
Parameter
No.
Factory
Setting
Name
Setting
Validation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com