Basic Programming 5 - 25
It is possible to compare the parameter values stored in the digital operator with the parameter values currently in the Drive by using
the VERIFY function. To do this, set o3-01=3. During the comparing of the parameter values into the Drive the digital operator will
display:
A successful VERIFY of the parameter values will display:
If all the parameter values stored in the digital operator do not match those programmed in the Drive, the digital operator displays the
following:
The digital operator will not display which parameters did not match, only that the verification found discrepancies in some parame-
ter values.
Yaskawa Electric America offers DriveWizard™ software that can also READ, COPY, and Verify Drive parameter values.
DriveWizard™ lists all discrepancies between the Drive and a pre-saved parameter file when verifying is performed.
NOTE: In order to properly use the COPY or VERIFY functions, the following Drive data must match that of the Drive from which
the digital operator stored its parameter values:
∗ Drive Product and type (e.g. E7)
∗ Software Number (e.g. 03010 also known as FLASH ID)
∗ Drive capacity and voltage e.g. CIMR-E7U4018 (480Vac, _A)
-
DV-
VERIFY
DATA VERIFYING
-
DV-
VERIFY
VERIFY COMPLETE
-
DV-
VYE
VERIFY ERROR