Electrical Installation
3
3.9 Braking Resistor Installation
YASKAWA SIEPC71061737B GA800 Drive Technical Reference 115
7. Tighten the nut to the specified torque.
Figure 3.70 Tighten the Terminal Block Nut
8. Attach the wiring cover and terminal block cover to their initial positions and tighten the screws on the terminal
block cover.
Figure 3.71 Reattach the Wiring Cover
9. Put the terminal cover back in its initial position.
Connect Braking Units in Parallel
To connect two or more braking units in parallel, refer to Figure 3.72 for wiring and connector selections.
Braking units have connectors to select master or slave. On the first braking unit, select the master side. On the
second unit and all subsequent units, select the slave side.
Figure 3.72 Connect Braking Units in Parallel