11.16 T: Motor Tuning
574 YASKAWA SIEPC71061737B GA800 Drive Technical Reference
No.
(Hex.)
Name Description
Default
(Range)
Ref.
T1-12
(0BDB)
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate
the motor with a light load attached after Stationary Auto-Tuning is complete, enable this
parameter.
Note:
You must first set T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz] to enable this
parameter.
0 : No
1 : Yes
0
(0, 1)
1000
T1-13
(0BDC)
No-load voltage
Sets the no-load voltage of the motor. If you know the no-load voltage at the rated speed in
a test report, set that voltage value. If you do not know the no-load voltage, do not change
from the initial value.
Note:
To get the same qualities as a Yaskawa 1000-series drive or previous models, set this
parameter = T1-03 [Motor Rated Voltage] value.
The default value is different for different models.
2004 - 2008, 4002 - 4004: T1-03 × 0.85
2010 - 2415, 4005 - 4302: T1-03 × 0.90
4371- 4720: T1-03 × 0.95
T1-03 × 0.85
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
1000
T2: PM Motor Auto-Tuning
No.
(Hex.)
Name Description
Default
(Range)
Ref.
T2-01
(0750)
PM Auto-Tuning
Selection
Sets the type of Auto-Tuning for PM motors.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
3 : Z-Pulse Offset (Pole Position)
4 : Rotational (Ld, Lq, R, back-EMF)
5 : High Frequency Injection
0
(Determined by A1-02)
1000
T2-02
(0751)
PM Motor Code Selection
If the drive is operating a Yaskawa PM motor from the SMRA, SSR1, or SST4 series,
enter the PM motor code in accordance with the rotation speed and motor output.
FFFF
(0000 - FFFF)
1001
T2-03
(0752)
PM Motor Type
Sets the type of PM motor the drive will operate.
0 : IPM motor
1 : SPM motor
1
(0, 1)
1001
T2-04
(0730)
PM Motor Rated Power
Uses the units set in o1-58 [Motor Power Unit Selection] to set the PM motor rated output
power.
Determined by o2-04,
C6-01
(0.00 - 650.00 HP)
1001
T2-05
(0732)
PM Motor Rated Voltage
Sets the rated voltage (V) of the motor.
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
1001
T2-06
(0733)
PM Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04
(10% to 200% of the
drive rated current)
1001
T2-07
(0753)
PM Motor Base
Frequency
Sets the base frequency (Hz) of the motor.
60.0 Hz
(0.0 - 590.0 Hz)
1001
T2-08
(0734)
Number of PM Motor
Poles
Sets the number of motor poles.
4
(2 - 48)
1002
T2-09
(0731)
PM Motor Base Speed
Sets the motor base speed (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 34500 min
-1
(r/min))
1002
T2-10
(0754)
PM Motor Stator
Resistance
Sets the stator resistance for each motor phase.
Note:
This parameter does not set line-to-line resistance.
Determined by T2-02
(0.000 - 65.000 Ω)
1002
T2-11
(0735)
PM Motor d-Axis
Inductance
Sets the d-axis inductance of the motor on a per phase basis.
Determined by T2-02
(0.00 - 600.00 mH)
1002
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA800 Series

Related product manuals