10.7 Drive Derating
446 YASKAWA SIEPC71061737B GA800 Drive Technical Reference
10.7 Drive Derating
You must derate the drive capacity to operate the drive above the rated temperature, altitude, and default carrier
frequency.
Carrier Frequency Settings and Rated Current Values
Table 10.17, Table 10.19, and Table 10.20 show how the drive rated output current changes when the C6-02 [Carrier
Frequency Selection] value changes. The output current value changes linearly as the carrier frequency changes. You
can use the values from the tables to calculate a frequency that is not shown. When A1-02 = 4, 6 [Control Method
Selection = AOLV, AOLV/PM], refer to Table 10.18, Table 10.21, and Table 10.22.
200 V Class
Table 10.17 Carrier Frequency and Rated Current Derating
Model
Rated Current (A)
Heavy Duty Rating (HD)
Parameter C6-01 = 0
Normal Duty Rating (ND)
Parameter C6-01 = 1
2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz
2004 3.5 3.5 3.5 3.4 3.2 3.06 4.2 4.0 3.6 3.4 3.1 2.77
2006 5.0 5.0 5.0 4.8 4.6 4.3 6 5.6 5 4.6 4.1 3.6
2008 6.9 6.9 6.9 6.5 5.9 5.4 8 7.6 6.9 6.5 5.9 5.4
2010 8.0 8.0 8.0 7.4 6.6 5.8 9.6 9.0 8 7.4 6.6 5.8
2012 11.0 11.0 11.0 10.4 9.6 8.8 12 11.7 11 10.5 9.9 9.3
2018 14.0 14.0 14.0 12.6 10.8 9.1 17.5 16.1 14 12.6 10.8 9.1
2021 17.5 17.5 17.5 16.1 14.3 12.6 21 19.6 17 16.1 14.3 12.5
2030 25.0 25.0 25.0 23.0 20.5 18.0 30 28.0 25 23.0 20.5 18.0
2042 33.0 33.0 33.0 29.3 24.8 20.2 42 38.4 33 29.4 24.9 20.4
2056 47.0 47.0 47.0 43.4 38.9 34.4 56 52.4 47 43.4 38.9 34.4
2070 60.0 60.0 60.0 56.0 51.0 46 70 66.0 60 56.0 51.0 46.0
2082 75.0 75.0 75.0 68.6 60.5 53 82 82.0 75 68.8 61.0 53.1
2110 88.0 88.0 88.0 80.5 71.0 62 110 102.7 92 84.3 75.2 66.0
2138 115.0 115.0 115.0 105.1 92.8 81 138 128.8 115 105.8 94.3 82.8
2169 145.0 145.0 125.2 112.0 - - 169 152.7 128.3 112.0 - -
2211 180.0 180.0 155.2 138.6 - - 211 190.2 158.9 138.1 - -
2257 215.0 215.0 184.8 164.7 - - 257 230.4 190.5 163.9 - -
2313 283.0 283.0 249.0 226.4 - - 313 288.5 251.7 227.1 - -
2360 346.0 346.0 294.3 259.8 - - 360 330.8 287.6 258.8 - -
2415 415.0 415.0 365.2 332.0 - - - - - - - -
Table 10.18 AOLVAOLV/PM Carrier Frequency and Rated Current Derating
Model
Rated Current (A)
Heavy Duty Rating (HD)
*1
Parameter C6-01 = 0
Normal Duty Rating (ND)
*1
Parameter C6-01 = 1
2 kHz
(2 kHz)
4 kHz
(-)
6 kHz
(5 kHz)
8 kHz
(8 kHz)
10 kHz
(10 kHz)
12 kHz
(12.5 kHz)
2 kHz
(2 kHz)
4 kHz
(-)
6 kHz
(5 kHz)
8 kHz
(8 kHz)
10 kHz
(10 kHz)
12 kHz
(12.5 kHz)
2004 3.5 3.5 3.4 3.2 3.1 2.9 4.2 3.8 3.5 3.1 2.8 2.4
2006 5.0 5.0 4.9 4.6 4.3 4.1 6.0 5.4 4.8 4.2 3.6 3.0
2008 6.9 6.9 6.7 6.0 5.4 4.7 8.0 7.3 6.7 6.0 5.4 4.7