EasyManua.ls Logo

YASKAWA GA800 Series - D5: Torque Control; D6: Field Weakening;Forcing

YASKAWA GA800 Series
1016 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.7 d: Reference Settings
506 YASKAWA SIEPC71061737B GA800 Drive Technical Reference
No.
(Hex.)
Name Description
Default
(Range)
Ref.
d4-09
(02B0)
RUN
Up/Down 2 Bias Lower
Limit
Sets the lower limit of the Up/Down 2 bias as a percentage of the Maximum Output
Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum
output frequency.
A1-02 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
0.0%
(-99.9 - 0.0%)
751
d4-10
(02B6)
Up/Down Freq Lower
Limit Select
Sets the lower frequency limit for the Up/Down function.
0 : Greater of d2-02 or Analog
1 : d2-02
0
(0, 1)
751
d5: Torque Control
No.
(Hex.)
Name Description
Default
(Range)
Ref.
d5-01
(029A)
Torque Control Selection
Sets the drive for torque control or speed control.
0 : Speed Control
1 : Torque Control
0
(0, 1)
755
d5-02
(029B)
Torque Reference Delay
Time
Sets the primary delay time constant for the torque reference filter.
Determined by A1-02
(0 - 1000 ms)
755
d5-03
(029C)
Speed Limit Selection
Sets the torque control speed limit method.
1 : Active Frequency Reference
2 : d5-04 Setting
1
(1, 2)
755
d5-04
(029D)
Speed Limit
Sets the speed limit during Torque Control as a percentage of E1-04 [Maximum Output
Frequency]. Set d5-03 = 2 [Speed Limit Selection = d5-04 Setting] before you set this
parameter.
0%
(-120 - +120%)
756
d5-05
(029E)
Speed Limit Bias
Sets the speed limit bias value as a percentage of E1-04 [Maximum Output Frequency].
10%
(0 - 120%)
756
d5-06
(029F)
Speed/Torque
Changeover Time
Sets the delay time to switch between Speed Control and Torque Control. Set H1-xx = 71
[MFDI Function Selection = Torque Control] before you set this parameter.
0 ms
(0 - 1000 ms)
756
d5-08
(02B5)
Uni-directional Speed
Limit Bias
Sets the direction of the speed limit reference to which Speed Limit Bias [d5-05] applies.
0 : Disabled
1 : Enabled
1
(0, 1)
756
d6: Field Weakening /Forcing
No.
(Hex.)
Name Description
Default
(Range)
Ref.
d6-01
(02A0)
Field Weakening Level
Sets the drive output voltage as a percentage of E1-05 [Maximum Output Voltage] when
H1-xx = 63 [Field Weakening] is activated.
80%
(0 - 100%)
757
d6-02
(02A1)
Field Weakening
Frequency Limit
Sets the minimum output frequency to start field weakening.
0.0 Hz
(0.0 - 590.0 Hz)
757
d6-03
(02A2)
Field Forcing Selection
Sets the field forcing function.
0 : Disabled
1 : Enabled
0
(0, 1)
757
d6-06
(02A5)
Field Forcing Limit
Sets the limit value for field forcing to increase the motor excitation current reference as a
percentage of E2-03 [Motor No-Load Current]. Usually it is not necessary to change this
setting.
400%
(100 - 400%)
757
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA800 Series

Related product manuals