EasyManua.ls Logo

YASKAWA GA800 Series - Common Drive Specifications

YASKAWA GA800 Series
1016 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
10
10.5 Common Drive Specifications
YASKAWA SIEPC71061737B GA800 Drive Technical Reference 439
10.5 Common Drive Specifications
Note:
To get the OLV, CLV, and AOLV specifications, do Rotational Auto-Tuning.
To get the longest product life, install the drive in an environment that meets the necessary specifications.
Table 10.9 Control Characteristics
Item Specification
Control Methods
V/f Control (V/f)
V/f Control with Encoder (CL-V/f)
Open Loop Vector (OLV)
Closed Loop Vector (CLV)
Advanced Open Loop Vector (AOLV)
PM Open Loop Vector (OLV/PM)
PM Advanced Open Loop Vector (AOLV/PM)
PM Closed Loop Vector (CLV/PM)
EZ Vector Control (EZOLV)
Carrier Frequency
Models 2004 to 2415 and 4002 to 4103:
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Models 4140 to 4720:
HD: 5 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 10 kHz maximum.
Maximum Output
Voltage
200 V Class: Three-phase 200 V to 240 V
400 V Class: Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
Frequency Control
Range
AOLVand EZOLV: 0.01 Hz to 120 Hz
CL-V/f, CLV, AOLV/PM, and CLV/PM: 0.01 Hz to 400 Hz
V/f, OLV, and OLV/PM: 0.01 Hz to 590 Hz
Frequency Accuracy
(Temperature
Fluctuation)
Digital inputs: Within ±0.01% of the maximum output frequency (-10 °C to +40 °C (14 °F to 104 °F))
Analog inputs: Within ±0.1% of the maximum output frequency (25 °C ±10 °C (77 °F ±18 °F))
Frequency Setting
Resolution
Digital inputs: 0.01 Hz
Analog inputs: 1/2048 of the maximum output frequency (11-bit signed)
Output Frequency
Resolution
0.001 Hz
Frequency Setting
Signal
Main speed frequency reference: -10 Vdc to +10 Vdc (20 kΩ), 0 Vdc to 10 Vdc (20 kΩ), 4 mA to 20 mA (250 Ω), 0 mA to 20 mA (250 Ω)
Main speed reference: Pulse train input (maximum 32 kHz)
Starting Torque
V/f: 150%/3 Hz
CL-V/f: 150%/3 Hz
OLV: 200%/0.3 Hz
CLV: 200%/0 min
-1
(r/min)
AOLV: 200%/0.3 Hz
OLV/PM: 100%/5% speed
AOLV/PM: 200%/0 min
-1
(r/min)
CLV/PM: 200%/0 min
-1
(r/min)
EZOLV: 100%/1% speed
Note:
Correctly select the drive and motor capacity for this starting torque in these control methods:
OLV
CLV
AOLV
AOLV/PM
CLV/PM

Table of Contents

Other manuals for YASKAWA GA800 Series

Related product manuals