1.2 Catalog Code and Nameplate Check
YASKAWA SIEPC71061737B GA800 Drive Technical Reference 25
Model
Heavy Duty Rating (HD)
Parameter C6-01 = 0
Normal Duty Rating (ND)
Parameter C6-01 = 1 (Default)
Maximum
Motor Output
kW (HP)
Rated Output Current
A
Maximum
Motor Output
kW (HP)
Rated Output Current
A
2313
75 (100) 283 90 (125) 313
2360
90 (125) 346 110 (150) 360
2415
110 (150) 415
110 (150) 415
Table 1.3 Output Current for Three-Phase 480 V Models
Model
Heavy Duty Rating (HD)
Parameter C6-01 = 0
Normal Duty Rating (ND)
Parameter C6-01 = 1 (Default)
Maximum
Motor Output
kW (HP)
Rated Output Current
A
Maximum
Motor Output
kW (HP)
Rated Output Current
A
4002 0.55 (0.75) 1.8 0.75 (1) 2.1
4004 1.1 (1.5) 3.4 1.5 (2) 4.1
4005 1.5 (2) 4.8 2.2 (3) 5.4
4007 2.2 (3) 5.5 3 (4) 7.1
4009 3.0 (4) 7.2 3.7 (5) 8.9
4012 3.7 (5) 9.2 5.5 (7.5) 11.9
4018 5.5 (7.5) 14.8 7.5 (10) 17.5
4023 7.5 (10) 18 11 (15) 23.4
4031 11 (15) 24 15 (20) 31
4038 15 (20) 31 18.5 (25) 38
4044 18.5 (25) 39 22 (30) 44
4060 22 (30) 45 30 (40) 59.6
4075 30 (40) 60 37 (50) 74.9
4089 37 (50) 75 45 (60) 89.2
4103 45 (60) 91 55 (75) 103
4140 55 (75) 112 75 (100) 140
4168 75 (100) 150 90 (125) 168
4208 90 (125) 180 110 (150) 208
4250 110 (150) 216 150 (200) 250
4302 150 (200) 260 185 (250) 302
4371 185 (250) 304 220 (300) 371
4414 220 (300) 371 260 (350) 414
4477 260 (350) 414 300 (400) 477
4568 300 (400) 477 335 (450) 568
4605 335 (450) 605 370 (500) 675
4720 370 (500) 605 450 (600) 720