Parameter List
11
11.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA SIEPC71061737B GA800 Drive Technical Reference 609
No. Name Unit Default
- Drive Model - 4031 4038 4044 4060
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 9C 9D 9E 9F
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP
(kW)
15
(11)
20
(15)
20
(15)
25
(18.5)
25
(18.5)
30
(22)
30
(22)
40
(30)
E2-03
(E4-03)
Motor No-
Load Current
A 5.6 7.6 7.6 7.8 7.8 9.2 9.2 10.9
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 0.922 0.55 0.55 0.403 0.403 0.316 0.316 0.269
E2-06
(E4-06)
Motor
Leakage
Inductance
% 19.6 17.2 17.2 20.1 20.1 23.5 23.5 20.7
E2-10
(E4-10)
Motor Iron
Loss
W 385 440 440 508 508 586 586 750
E5-01
PM Motor
Code Selection
- FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF
L2-02
Power Loss
Ride Through
Time
s 2 2 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 0.9 1 1 1 1 1 1 1.1
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.6 0.6 0.6 0.6 0.6 0.6 0.6
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 380 380 380 380 380 380 380 380
L3-24
Motor Accel
Time for
Inertia Cal
s 0.265 0.244 0.244 0.317 0.317 0.355 0.355 0.323
L8-02
Overheat
Alarm Level
°C 115 115 120 120 120 120 130 137
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 2 2 2 2 2 2 2 2
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
n5-02
Motor Inertia
Acceleration
Time
s 0.265 0.244 0.244 0.317 0.317 0.355 0.355 0.323
*1 Parameters within parentheses are for motor 2.