EasyManua.ls Logo

YASKAWA GA800 Series - Page 947

YASKAWA GA800 Series
1016 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
12
12.9 L: Protection Functions
YASKAWA SIEPC71061737B GA800 Drive Technical Reference 947
L8-53: STPo Integration Time
No.
(Hex.)
Name Description
Default
(Range)
L8-53
(0473)
Expert
STPo Integration Time
Sets the length of time until the drive detects STPo after it is more than the value of L8-51 [STPo I
Detection Level].
1.0 s
(1.0 - 10.0 s)
L8-54: STPo Id Diff Detection
No.
(Hex.)
Name Description
Default
(Range)
L8-54
(0474)
Expert
STPo Id Diff Detection
Sets the Id deviation detection function for STPo [Motor Step-Out Detected].
1
(0, 1)
0 : Disabled
1 : Enabled
L8-55: Internal DB TransistorProtection
No.
(Hex.)
Name Description
Default
(Range)
L8-55
(045F)
Internal DB
TransistorProtection
Sets the protection function for the internal braking transistor.
1
(0, 1)
0 : Disable
Disables braking transistor protection.
Use this setting, if enabling the braking transistor can cause an rF [Braking Resistor Fault] in these conditions:
With a regenerative converter, for example D1000.
With a regenerative unit, for example R1000.
When connecting braking resistor options to the drive, for example CDBR units.
Without an internal braking transistor.
1 : Protection Enabled
Prevents damage to the internal braking transistor when using a braking transistor or optional braking resistors.
These models have a built-in braking transistor:
2004 to 2138
4002 to 4168
L8-56: Stall P @ Accel Activation Time
No.
(Hex.)
Name Description
Default
(Range)
L8-56
(047D)
Expert
Stall P @ Accel Activation
Time
Sets the length time that the acceleration stall prevention function can continue to operate before the
drive detects an STPo [Motor Step-Out Detected].
5000 ms
(100 - 5000 ms)
Note:
If this value is too small, it can cause incorrect detection of STPo. If this value is too large, the drive will not detect STPo.
L8-57: Stall Prevention Retry Counts
No.
(Hex.)
Name Description
Default
(Range)
L8-57
(047E)
Expert
Stall Prevention Retry
Counts
Sets the number of times the acceleration stall prevention function can operate until speeds agree
before the drive detects an STPo [Motor Step-Out Detected].
10
(1 - 10 times)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV