n040
Multi-function 22 Timer Start Cmd Timer function 2 to 29 11 5.19
Input Selection 23 OH3 Input OH3 (pre-alarm input)
(Terminal S6 Sel) 24 Ref Sample Hold Analog reference
Sample/Hold command
(Terminal S6 25 KEB Cmd (NO) Inertia ridethrough
Sel) command (N.O.)
26 KEB Cmd (NC) Inertia ridethrough
command (N.C.)
27 Hold Command Accel / Decel Ramp Hold
28 PID Polarity Sel PID changeover
29 Up/Down Control Up/Down Command
[ can only be set in
n040
]
n041
Multi-function LED LCD 0 to 17 0 5.20
Output Setting
Setting Description
(Terminals 0 Fault ** Fault
MA-MB-MC) 1 During Running During running
2 At Speed Speed agree
(Terminal 3 At Desired Speed Desired speed agree
MA Sel) 4 Freq Detection 1 Frequency detection 1
5 Freq Detection 2 Frequency detection 2
6 OverTrq De (NO) Overtorque / undertorque
detection (N.O.)
7 OverTrq Det (NC) Overtorque / undertorque
detection (N.C.)
8 BaseBlocked During base block
9 Operation mode Operation mode
n042
Multi-function 10 Ready Ready 0 to 17 1 5.20
Output 11 Timer Output Timer function
(Terminals 12 Auto Restarting During auto restart
M1-M2) 13 OL Pre-Alarm OL pre-alarm (80% of
OL1 or OL2)
(Terminal M1 14 Freq Ref Loss Frequency reference loss
Sel) 15 Set By COM Cntl Closed by serial comm.
16 PID Fdbk Loss PID feedback loss
17 OH1 Alarm OH1 alarm (functions only if
n035
has been set to " 3 ")
n043
Analog LED LCD Auto/Man 0 to 4 0 5.11,
Input Selection Setting
Setting
FV FI Switch 5.22B
0
FV=MSTR FI=AUX**
Auto Man Yes
(AnalogInput 1 FV=AUX FI=MSTR Man Auto Yes
Sel) 2 FV=RST FI=MSTR Flt Rst Auto No
3 FV=MSTR FI=SQRT Auto N No
4 FV=RST FI=SQRT Flt Rst N No
n044
Terminal FI LED LCD 0 or 1 1 5.11,
Signal Level Setting
Setting Description 5.22B
Selection 0 0-10 VDC 0-10V input (jumper J1 on
(Terminal FI Control PCB must be cut)
Sel) 1 4-20 mA** 4-20mA input
Table A1-1. Drive Parameters (
nXXX
) – Continued
PARAM.
FUNCTION NAME SETTING FACTORY USER PARA.
NO. (ACTUAL DISPLAY)
DESCRIPTION
RANGE SETTING ** SETTING REF.
A1-6

Table of Contents